Mengenbereich (Einheit) | Preis (pro Einheit) | Rabatt |
10 | $115.00 | $35.00 |
20 | $105.00 | $45.00 |
50 | $95.00 | $55.00 |
Specifications:
Output |
Range |
Input range |
Resolution |
Accuracy |
Explanation |
Voltage |
10V |
0.000 ~11.000V |
1mV |
±0.05% Setting value ±2mV |
The max.output current is 10mA |
Current |
20mA |
0.000~22.000mA |
0.001mA |
±0.05% Setting value ±4uA |
20mA,the max.overload is 1kΩ(Note1) |
Analogue transducer(absorption) |
-20mA |
0.000~-22.000mA |
0.001mA |
±0.1% Setting value ±4uA |
20mA,the max.overload is 1kΩ |
Loop power |
24V |
|
|
±10% |
The max.output current is 25mA |
Power |
9V battery (ANSI/NEDA 1640A or IEC 6LR619 alkaline) or AC power adapter |
Battery |
Approx. 20 hours under the condition of 10mA |
Max.allowable voltage |
30V |
Operation temperture range |
0-50°C |
Operation humidity range |
≤80%RH |
Store temperature range |
≤-10°C-50°C |
Store humidity range |
≤90%RH |
Size |
200×100×40mm |
Weight |
550g(with holster) |
Accessories |
Operation manual,test line CF-36(probe with alligator clip) |
Options |
AC adapter(VCPS),test line CF-31-A(probe clip) |
Security |
Conforms to IEC 1010 |
Note:
1.The max.overlaod is 1kΩ at 20mA range when the power is higher than 6.8V,
The max.overlaod is 700Ω at 20mA range when the power is higher than 5.8-6.8V,
2.Temperature coefficient:±0.005%,range/°C(5°C-28°C,18°C-40°C)